← Industries

Electric Arc Furnace

Electric Arc Furnace — standard dust collection design

Dust characteristics

  • • Dust: Iron oxide fume
  • • d50: 0.5 μm
  • • Particle density: 5000 kg/m³

Gas conditions

  • • Operating temperature: 300°C
  • • Typical concentration: 15 g/Nm³

Standard train

Air-cooled HX → Pulse-jet baghouse (Nomex)
Target outlet: 10 mg/Nm³

Typical Electric Arc Furnace values are prefilled — replace them with your site data.