Dust characteristics
- • Dust: Iron oxide fume
- • d50: 0.5 μm
- • Particle density: 5000 kg/m³
Gas conditions
- • Operating temperature: 300°C
- • Typical concentration: 15 g/Nm³
Standard train
Air-cooled HX → Pulse-jet baghouse (Nomex)
Target outlet: 10 mg/Nm³