Dust characteristics

  • • Dust: Grain dust
  • • d50: 100 μm
  • • Particle density: 800 kg/m³
  • • ⚠ Explosible (Kst 150)

Gas conditions

  • • Operating temperature: 25°C
  • • Typical concentration: 15 g/Nm³

Standard train

Cyclone → Baghouse (ATEX)
Target outlet: 30 mg/Nm³

References

  • NFPA 61
  • EN 14034