← Industries
Coal Power Plant
Coal Power Plant — standard dust collection design
Dust characteristics
- • Dust: Coal fly ash
- • d50: 8 μm
- • Particle density: 2400 kg/m³
- • Resistivity: 1e+10 Ω·cm
Gas conditions
- • Operating temperature: 150°C
- • SO₂: 400 ppm
- • NOx: 300 ppm
- • Typical concentration: 15 g/Nm³
Standard train
Large ESP → SCR or semi-dry (SDA) → Secondary baghouse
Target outlet: 5 mg/Nm³
Typical Coal Power Plant values are prefilled — replace them with your site data.