Coal Power Plant — standard dust collection design

Dust characteristics

  • • Dust: Coal fly ash
  • • d50: 8 μm
  • • Particle density: 2400 kg/m³
  • • Resistivity: 1e+10 Ω·cm

Gas conditions

  • • Operating temperature: 150°C
  • • SO₂: 400 ppm
  • • NOx: 300 ppm
  • • Typical concentration: 15 g/Nm³

Standard train

Large ESP → SCR or semi-dry (SDA) → Secondary baghouse
Target outlet: 5 mg/Nm³

Typical Coal Power Plant values are prefilled — replace them with your site data.